Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.234
Filter
1.
Am J Perinatol ; 39(2): 204-215, 2022 01.
Article in English | MEDLINE | ID: mdl-32781477

ABSTRACT

OBJECTIVE: This study aimed to detect which of the two main medicines suggested in the treatment of postligation cardiac syndrome (PLCS)-dobutamine or mirinone-possesses a more therapeutic effect. While doing this, clinicians are provided with a broader perspective on the treatment and follow-up of cases. The desire was to increase the treatability and monitor ability of the cases in question and hence their survivability. STUDY DESIGN: A retrospective review of a cohort of infants with PLCS was conducted between March 2012 and December 2018. In the treatment of infants with PLCS, dobutamine (dobutamine study group-DSG) or milrinone (milrinone study group-MSG) was used. The respiration, cardiac, echocardiography, and perfusion parameters of the cases were assessed both before and after ligation. Based on the data obtained, both the effects of the medicines on PLCS and the difference between their therapeutic effects were studied. The accuracy of prognostication was assessed with receiver operating characteristic analyses. RESULTS: PLCS was detected in 29 (34.1%) of 85 patent ductus arteriosus ligation cases in total. Of all the PLCS cases, 13 (44.8%) were treated with dobutamine and 16 (55.2%) with milrinone. It was observed that the effects of the medicines on the respiratory system and cardiovascular system manifested in the third and 6th hour, respectively. It was detected that both medicines had more effect on the systolic blood pressure (SBP) (area under the curve [AUC]: 0.997/0.996, p = 0.001/0.002) than on the diastolic blood pressure (AUC: 0.911/0.843, p = 0.032/0.046). CONCLUSION: Dobutamine and milrinone, two primary medicines that can be used in the treatment of cases with PLCS, possess similar therapeutic effects on this pathology. In addition, their postoperative therapeutic effects on the SBP are more in the foreground.


Subject(s)
Cardiotonic Agents/administration & dosage , Cardiovascular System/drug effects , Dobutamine/administration & dosage , Milrinone/administration & dosage , Postoperative Complications/drug therapy , Cardiac Output/drug effects , Ductus Arteriosus, Patent/surgery , Echocardiography , Female , Humans , Infant , Infant, Newborn , Infant, Premature , Ligation , Male , Respiration/drug effects , Retrospective Studies , Treatment Outcome
3.
ABC., imagem cardiovasc ; 35(2): eabc264, 2022. ilus, tab
Article in Portuguese | LILACS | ID: biblio-1400505

ABSTRACT

Embora a avaliação da viabilidade miocárdica seja comum na prática do cardiologista, muitos médicos têm dúvidas a respeito dos resultados dos métodos diagnósticos. A medicina nuclear tem papel importante nos estudos de viabilidade, mas os laudos precisam ser interpretados num contexto clínico e fisiopatológico. Este artigo teve o objetivo de revisar a origem e a evolução do conceito da viabilidade miocárdica. São expostos os métodos diagnósticos com ênfase na medicina nuclear com uma explicação funcional sobre cada tipo de exame. A partir disso, são mostradas imagens como exemplos e é proposta uma maneira de atuar nesses casos baseada na clínica, na porcentagem de miocárdio acometido e na topografia das lesões coronarianas (proximais ou distais). (AU)


Although assessing myocardial viability is a common cardiology practice, many physicians question the results of diagnostic methods. Nuclear medicine plays an important role in viability studies, but the reports require interpretation in a clinical and pathophysiological context. this article was aimed at reviewing the origin and evolution of myocardial viability. Here we present diagnostic methods by emphasizing nuclear medicine and provide a functional explanation of each test type using example images. We also propose how to act in these cases based on clinic examination findings, the percentage of affected myocardium, and coronary lesion topography (proximal or distal).(AU)


Subject(s)
Humans , Echocardiography/methods , Myocardial Stunning/diagnosis , Myocardial Stunning/physiopathology , Ventricular Dysfunction, Left/therapy , Nuclear Medicine/instrumentation , Rubidium/administration & dosage , Thallium/administration & dosage , Tomography, Emission-Computed, Single-Photon/methods , Clinical Diagnosis , Echocardiography, Stress/methods , Positron-Emission Tomography/methods , Dobutamine/administration & dosage , Myocardial Revascularization/methods
4.
J Am Heart Assoc ; 10(13): e020597, 2021 07 06.
Article in English | MEDLINE | ID: mdl-34151580

ABSTRACT

Background Functional assessment of myocardial bridging (MB) remains clinically challenging because of the dynamic nature of the extravascular coronary compression with a certain degree of intraluminal coronary reduction. The aim of our study was to assess performance and diagnostic value of diastolic-fractional flow reserve (d-FFR) during dobutamine provocation versus conventional-FFR during adenosine provocation with exercise-induced myocardial ischemia as reference. Methods and Results This prospective study includes 60 symptomatic patients (45 men, mean age 57±9 years) with MB on the left anterior descending artery and systolic compression ≥50% diameter stenosis. Patients were evaluated by exercise stress-echocardiography test, and both conventional-FFR and d-FFR in the distal segment of left anterior descending artery during intravenous infusion of adenosine (140 µg/kg per minute) and dobutamine (10-50 µg/kg per minute), separately. Exercise-stress-echocardiography test was positive for myocardial ischemia in 19/60 patients (32%). Conventional-FFR during adenosine and peak dobutamine had similar values (0.84±0.04 versus 0.84±0.06, P=0.852), but d-FFR during peak dobutamine was significantly lower than d-FFR during adenosine (0.76±0.08 versus 0.79±0.08, P=0.018). Diastolic-FFR during peak dobutamine was significantly lower in the exercise-stress-echocardiography test -positive group compared with the exercise- stress-echocardiography test -negative group (0.70±0.07 versus 0.79±0.06, P<0.001), but not during adenosine (0.79±0.07 versus 0.78±0.09, P=0.613). Among physiological indices, d-FFR during peak dobutamine was the only independent predictor of functionally significant MB (odds ratio, 0.870; 95% CI, 0.767-0.986, P=0.03). Receiver-operating characteristics curve analysis identifies the optimal d-FFR during peak dobutamine cut-off ≤0.76 (area under curve, 0.927; 95% CI, 0.833-1.000; P<0.001) with a sensitivity, specificity, and positive and negative predictive value of 95%, 95%, 90%, and 98%, respectively, for identifying MB associated with stress-induced ischemia. Conclusions Diastolic-FFR, but not conventional-FFR, during inotropic stimulation with high-dose dobutamine, in comparison to vasodilatation with adenosine, provides more reliable functional significance of MB in relation to stress-induced myocardial ischemia.


Subject(s)
Adenosine/administration & dosage , Cardiotonic Agents/administration & dosage , Echocardiography, Stress , Fractional Flow Reserve, Myocardial , Myocardial Bridging/diagnostic imaging , Myocardial Ischemia/diagnostic imaging , Vasodilator Agents/administration & dosage , Adult , Aged , Diastole , Dobutamine/administration & dosage , Exercise Test , Feasibility Studies , Female , Humans , Male , Middle Aged , Myocardial Bridging/complications , Myocardial Bridging/physiopathology , Myocardial Ischemia/etiology , Myocardial Ischemia/physiopathology , Predictive Value of Tests , Prospective Studies , Reproducibility of Results
5.
Exp Neurol ; 341: 113687, 2021 07.
Article in English | MEDLINE | ID: mdl-33713656

ABSTRACT

BACKGROUND: In the adult brain, increases in neural activity lead to increases in local blood flow. However, in the preterm neonate, studies of cerebral functional haemodynamics have yielded inconsistent results, including negative responses suggesting decreased perfusion and localised tissue hypoxia, probably due to immature neurovascular coupling. Furthermore, the impact of vasoactive medications, such as dopamine and dobutamine used as inotropic therapies in preterm neonates, on cerebrovascular responses to somatosensory input is unknown. We aimed to characterise the cerebral haemodynamic functional response after somatosensory stimulation in the preterm newborn brain, with and without dopamine or dobutamine treatment. METHODS: We studied the cerebral haemodynamic functional response in 13 anaesthetised preterm lambs, using near infrared spectroscopy to measure changes in cerebral oxy- and deoxyhaemoglobin (ΔoxyHb, ΔdeoxyHb) following left median nerve stimulation using stimulus trains of 1.8, 4.8 and 7.8 s. The 4.8 and 7.8 s stimulations were repeated during dopamine or dobutamine infusion. RESULTS: Stimulation always produced a somatosensory evoked response. Majority of preterm lambs demonstrated positive functional responses (i.e. increased ΔoxyHb) in the contralateral cortex following stimulus trains of all durations. Dopamine increased baseline oxyHb and total Hb, whereas dobutamine increased baseline deoxyHb. Both dopamine and dobutamine reduced the evoked ΔoxyHb responses to 4.8 and 7.8 s stimulations. CONCLUSIONS: Somatosensory stimulation increases cerebral oxygenation in the preterm brain, consistent with increased cerebral blood flow due to neurovascular coupling. Notably, our results show that dopamine/dobutamine reduces oxygen delivery relative to consumption in the preterm brain during somatosensory stimulations, suggesting there may be a risk of intermittent localised tissue hypoxia which has clear implications for clinical practice and warrants further investigation.


Subject(s)
Cerebrovascular Circulation/drug effects , Dobutamine/administration & dosage , Dopamine/administration & dosage , Evoked Potentials, Somatosensory/drug effects , Hemodynamics/drug effects , Somatosensory Cortex/drug effects , Animals , Animals, Newborn , Cardiotonic Agents/administration & dosage , Cerebrovascular Circulation/physiology , Evoked Potentials, Somatosensory/physiology , Female , Hemodynamics/physiology , Infusions, Intravenous , Male , Pregnancy , Sheep , Somatosensory Cortex/physiology , Spectroscopy, Near-Infrared/methods
6.
Expert Rev Cardiovasc Ther ; 19(4): 325-335, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33739204

ABSTRACT

Introduction: In the 20 years since its introduction to the palette of intravenous hemodynamic therapies, the inodilator levosimendan has established itself as a valuable asset for the management of acute decompensated heart failure. Its pharmacology is notable for delivering inotropy via calcium sensitization without an increase in myocardial oxygen consumption.Areas covered: Experience with levosimendan has led to its applications expanding into perioperative hemodynamic support and various critical care settings, as well as an array of situations associated with acutely decompensated heart failure, such as right ventricular failure, cardiogenic shock with multi-organ dysfunction, and cardio-renal syndrome. Evidence suggests that levosimendan may be preferable to milrinone for patients in cardiogenic shock after cardiac surgery or for weaning from extracorporeal life support and may be superior to dobutamine in terms of short-term survival, especially in patients on beta-blockers. Positive effects on kidney function have been noted, further differentiating levosimendan from catecholamines and phosphodiesterase inhibitors.Expert opinion:Levosimendan can be a valuable resource in the treatment of acute cardiac dysfunction, especially in the presence of beta-blockers or ischemic cardiomyopathy. When attention is given to avoiding or correcting hypovolemia and hypokalemia, an early use of the drug in the treatment algorithm is preferred.


Subject(s)
Cardiotonic Agents/therapeutic use , Heart Failure/drug therapy , Simendan/therapeutic use , Adrenergic beta-Antagonists/therapeutic use , Cardiac Surgical Procedures , Critical Care , Dobutamine/administration & dosage , Heart Failure/physiopathology , Hemodynamics/drug effects , Humans , Shock, Cardiogenic/drug therapy
7.
Sci Rep ; 11(1): 683, 2021 01 12.
Article in English | MEDLINE | ID: mdl-33436841

ABSTRACT

Ballistocardiography (BCG) and Seismocardiography (SCG) assess the vibrations produced by cardiac contraction and blood flow, respectively, by means of micro-accelerometers and micro-gyroscopes. From the BCG and SCG signals, maximal velocities (VMax), integral of kinetic energy (iK), and maximal power (PMax) can be computed as scalar parameters, both in linear and rotational dimensions. Standard echocardiography and 2-dimensional speckle tracking imaging echocardiography were performed on 34 healthy volunteers who were infused with increasing doses of dobutamine (5-10-20 µg/kg/min). Linear VMax of BCG predicts the rates of left ventricular (LV) twisting and untwisting (both p < 0.0001). The linear PMax of both SCG and BCG and the linear iK of BCG are the best predictors of the LV ejection fraction (LVEF) (p < 0.0001). This result is further confirmed by mathematical models combining the metrics from SCG and BCG signals with heart rate, in which both linear PMax and iK strongly correlate with LVEF (R = 0.7, p < 0.0001). In this setting of enhanced inotropism, the linear VMax of BCG, rather than the VMax of SCG, is the metric which best explains the LV twist mechanics, in particular the rates of twisting and untwisting. PMax and iK metrics are strongly associated with the LVEF and account for 50% of the variance of the LVEF.


Subject(s)
Ballistocardiography/methods , Dobutamine/administration & dosage , Echocardiography/methods , Heart Ventricles/physiopathology , Myocardial Contraction , Ventricular Function, Left/physiology , Adolescent , Adult , Cardiotonic Agents/administration & dosage , Female , Healthy Volunteers , Heart Rate , Humans , Male , Middle Aged , Randomized Controlled Trials as Topic , Retrospective Studies , Young Adult
8.
Int J Cardiovasc Imaging ; 37(4): 1321-1331, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33433744

ABSTRACT

Dobutamine stress echocardiography (DSE) is sensitive but subjective diagnostic tool to detect inducible ischemia. Nowadays, speckle tracking allows an objective quantification of regional wall function. We aimed to investigate the feasibility and accuracy of global (GLS) and regional longitudinal strain (RLS) during DSE to detect significant coronary stenosis (SCS). We conducted a prospective observational multicenter study including patients undergoing DSE for suspected SCS. 50 patients with positive DSE underwent coronary angiography. Besides visual regional wall motion score index (WMSI), GLS and RLS were determined at rest and at peak stress by Automated Function Imaging. DSE GLS feasibility was 96%. Among 35 patients with SCS, 12 patients were affected by multivessel disease, 18 had stenosis of left anterior descending artery (LAD), 18 of left circumflex (LCX) and 15 of right coronary artery (RCA). At peak stress, both GLS reduction (p = 0.037) and WMSI worsening (p = 0.04) showed significant agreement with coronary angiography for detecting SCS. When single lesion was considered, peak stress GLS and LAD RLS were lower in the obstructed LAD regions than in normo-perfused territories (17.4 ± 5.5 vs. 20.5 ± 4.4%, p = 0.03; 17.1 ± 7.6 vs. 21.6 ± 5.5%, p < 0.02, respectively). Furthermore, the addition of RLS to regional WMSI was able to improve accuracy in LAD SCS prediction (AUC 0.68, p = 0.037). Conversely, in presence of LCX or RCA SCS, LS was less accurate than WMSI at peak stress. In conclusion, DSE strain analysis is feasible and may improve prediction of LAD SCS, whereas regional WMSI assessment performs better in presence of SCS of LCX and RCA.


Subject(s)
Adrenergic beta-1 Receptor Agonists/administration & dosage , Coronary Artery Disease/diagnostic imaging , Coronary Stenosis/diagnostic imaging , Dobutamine/administration & dosage , Echocardiography, Stress , Aged , Coronary Artery Disease/physiopathology , Coronary Stenosis/physiopathology , Feasibility Studies , Female , Humans , Italy , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Reproducibility of Results , Severity of Illness Index
10.
Radiol Med ; 126(3): 356-364, 2021 Mar.
Article in English | MEDLINE | ID: mdl-32833196

ABSTRACT

The progressive increase in numbers of noninvasive cardiac imaging examinations broadens the spectrum of knowledge radiologists are expected to acquire in the management of drugs during CT coronary angiography (CTCA) and cardiac MR (CMR) to improve image quality for optimal visualization and assessment of the coronary arteries and adequate MR functional analysis. Aim of this review is to provide an overview on different class of drugs (nitrate, beta-blockers, ivabradine, anxiolytic, adenosine, dobutamine, atropine, dipyridamole and regadenoson) that can be used in CTCA and CMR, illustrating their main indications, contraindications, efficacy, mechanism of action, metabolism, safety, side effects or complications, and providing advices in their use.


Subject(s)
Cardiac Imaging Techniques , Computed Tomography Angiography/methods , Coronary Angiography/methods , Coronary Vessels/diagnostic imaging , Heart/diagnostic imaging , Magnetic Resonance Imaging/methods , Adenosine/administration & dosage , Adrenergic beta-Antagonists/administration & dosage , Adrenergic beta-Antagonists/adverse effects , Adrenergic beta-Antagonists/pharmacokinetics , Anti-Anxiety Agents/administration & dosage , Atropine/administration & dosage , Calcium Channel Blockers/administration & dosage , Calcium Channel Blockers/adverse effects , Contraindications, Drug , Dipyridamole/administration & dosage , Dobutamine/administration & dosage , Humans , Ivabradine/administration & dosage , Ivabradine/adverse effects , Nitroglycerin/administration & dosage , Purines/administration & dosage , Purines/adverse effects , Pyrazoles/administration & dosage , Pyrazoles/adverse effects , Vasodilator Agents/administration & dosage
11.
J Cardiovasc Transl Res ; 14(4): 735-743, 2021 08.
Article in English | MEDLINE | ID: mdl-32253745

ABSTRACT

Vortex formation time (VFT) is a dimensionless index used to quantify duration of vortex ring formation during diastole. We sought to investigate the effect of pharmaceutical stress on VFT in patients evaluated for ischemia. For this purpose, a standard dobutamine stress echo (DSE) protocol was performed in 50 consecutive patients, and VFT was calculated at rest and at peak. VFT was calculated from echocardiography measurements using a previously developed mathematical equation. VFTi was calculated as the percentage of change of VFTpeak, compared with VFTrest. Mean VFTrest was 2.46 (0.73) and mean VFTpeak 1.67 (0.57) with mean VFTi - 30.0% (19.8). In 14 (28%) patients, an ischemic response (DSE+) was documented. VFTi was significantly lower in DSE+ patients a finding which remained significant in the multivariate analysis after adjusting for age, sex, hypertension, diabetes, history of coronary artery disease, and relative increase of heart rate during stress. Graphical Abstract.


Subject(s)
Adrenergic beta-1 Receptor Agonists/administration & dosage , Coronary Circulation , Dobutamine/administration & dosage , Echocardiography, Stress , Hemodynamics , Myocardial Ischemia/diagnostic imaging , Aged , Blood Flow Velocity , Cross-Sectional Studies , Female , Humans , Male , Middle Aged , Myocardial Ischemia/physiopathology , Observer Variation , Predictive Value of Tests , Prognosis , Reproducibility of Results , Risk Assessment , Risk Factors
12.
ABC., imagem cardiovasc ; 33(4): eabc110, 20200000.
Article in Portuguese | LILACS | ID: biblio-1146299

ABSTRACT

Fundamento: Durante o ecocardiograma sob estresse com dobutamina, podem ocorrer efeitos adversos e exames inconclusivos. Objetivo: Avaliar em uma grande população geral a segurança e a exequibilidade do ecocardiograma sob estresse com dobutamina. Métodos: Estudo de 10.006 ecocardiogramas sob estresse com dobutamina realizados no período de julho de 1996 a setembro de 2007. A dobutamina foi administrada em quatro estágios (10, 20, 30 e 40 µcg.kg-1.min-1) para pesquisa de isquemia miocárdica e iniciada com 5 µcg.kg- ¹.min-1 apenas na análise de viabilidade miocárdica. A atropina foi iniciada conforme os protocolos vigentes. Foram verificados dados clínicos, hemodinâmicos e efeitos adversos associados ao ecocardiograma sob estresse com dobutamina. Resultados: Durante os ecocardiogramas sob estresse com dobutamina, ocorreu angina típica (8,9%), pico hipertensivo (1,7%), ectopias ventriculares isoladas (31%), taquiarritmia supraventricular (1,89%), fibrilação atrial (0,76%) e taquicardia ventricular não sustentada (0,6%). Os efeitos adversos citados foram mais frequentes nos pacientes com ecocardiogramas sob estresse com dobutamina positivos para isquemia. A desaceleração sinusal paradoxal (0,16%) não ocorreu em ecocardiogramas sob estresse com dobutamina positivo. As três complicações graves ocorreram em ecocardiogramas sob estresse com dobutamina positivos para isquemia. Foram dois casos (0,02%) com fibrilação ventricular e um caso de síndrome coronariana aguda (0,01%). Não houve caso de taquicardia ventricular sustentada, ruptura cardíaca, assistolia ou óbito. Comparados aos exames concluídos, nos inconclusivos, os pacientes usaram menos atropina (81,5% versus 49,9%; p< 0,001) e mais betabloqueador (4,7% versus 19%; p< 0,001), apresentando mais pico hipertensivo (1,1% versus 14,2%; p = 0,0001) e taquicardia ventricular não sustentada (0,5% versus 2,2%; p< 0,001). Conclusão: O ecocardiograma sob estresse com dobutamina realizado de forma apropriada é seguro e apresenta elevada exequibilidade.


Background: Adverse effects and inconclusive results may occur on dobutamine stress echocardiography. Objective: To assess the safety and feasibility of dobutamine stress echocardiography in a large general population. Methods: A total of 10,006 dobutamine stress echocardiographies were performed between July 1996 and September 2007. Dobutamine was administered in four stages (10, 20, 30, and 40 µcg·kg-1·min-1) to research myocardial ischemia starting with 5 µcg·kg- ¹·min-1 to analyze myocardial viability. Atropine administration was initiated according to current protocols. Clinical, hemodynamic, and adverse effect data associated with dobutamine stress echocardiography findings were verified. Results: Typical angina (8.9%), hypertensive peak (1.7%), isolated ventricular ectopias (31%), supraventricular tachyarrhythmia (1.89%), atrial


Subject(s)
Humans , Male , Female , Aged , Coronary Disease/diagnosis , Drug-Related Side Effects and Adverse Reactions , Atropine/administration & dosage , Retrospective Studies , Risk Factors , Echocardiography, Stress/adverse effects , Echocardiography, Stress/drug effects , Dobutamine/administration & dosage , Dobutamine/adverse effects , Electrocardiography/methods , Hypertension/complications , Metoprolol/administration & dosage
13.
BMC Pharmacol Toxicol ; 21(1): 82, 2020 11 25.
Article in English | MEDLINE | ID: mdl-33239108

ABSTRACT

BACKGROUND: To study the pharmacokinetic and -dynamic behavior of landiolol in the presence of dobutamine in healthy subjects of European ancestry. METHODS: We conducted a single-center, prospective randomized study in 16 healthy subjects each receiving an infusion of dobutamine sufficient to increase heart rate by 30 bpm followed by a 60 min infusion of 10 µg/kg/min landiolol. RESULTS: Dobutamine-induced increases in heart rate were stable for at least 20 min before a 60 min landiolol- infusion was started. The dobutamine effects were rapidly antagonized by landiolol within 16 min. A further slight decrease in heart rate during 20-60 min of the landiolol infusion occurred as well. Upon termination of landiolol infusion, heart rate and blood pressure recovered rapidly in response to the persisting dobutamine infusion but did not return to the maximum values before landiolol infusion. The pharmacokinetic parameters of landiolol in presence of dobutamine showed a short half-life (3.5 min) and a low distribution volume (0.3 l/kg). No serious adverse events were observed. CONCLUSION: Landiolol can antagonize the dobutamine-induced increases in heart rate and blood pressure in a fast way. A rapid bradycardic effect until steady-state plasma levels is followed by a slow heart rate reduction. The latter can be attributed to an early desensitization to dobutamine. Consequently, after termination of landiolol, the heart rate did not achieve maximum pre-landiolol values. The pharmacokinetics of landiolol during dobutamine infusion are similar when compared to short- and long-term data in Caucasian subjects. Landiolol in the given dose can thus serve as an antagonist of dobutamine-induced cardiac effects. TRIAL REGISTRATION: Registration number 2010-023311-34 at the EU Clinical Trials Register, registration date 2010-12-21.


Subject(s)
Adrenergic beta-Antagonists/pharmacokinetics , Blood Pressure/drug effects , Cardiotonic Agents/pharmacokinetics , Dobutamine/pharmacokinetics , Heart Rate/drug effects , Morpholines/pharmacokinetics , Urea/analogs & derivatives , Adrenergic beta-Antagonists/administration & dosage , Adult , Blood Pressure/physiology , Cardiotonic Agents/administration & dosage , Cross-Over Studies , Dobutamine/administration & dosage , Double-Blind Method , Female , Healthy Volunteers , Heart Rate/physiology , Humans , Infusions, Intravenous , Male , Morpholines/administration & dosage , Prospective Studies , Urea/administration & dosage , Urea/pharmacokinetics , Young Adult
14.
Circ J ; 84(10): 1818-1825, 2020 09 25.
Article in English | MEDLINE | ID: mdl-32893238

ABSTRACT

BACKGROUND: Sequential assessment using CT coronary angiography (coronary CT) and nuclear myocardial perfusion imaging (MPI) is considered an anatomical and functional evaluation of coronary artery disease (CAD). However, there can be unexpected radiation exposure. Hybrid MPI with stress-only nuclear MPI and rest CT-MPI using coronary CT may contribute to reducing the radiation dose in sequential assessment with nuclear MPI after coronary CT. We analyzed the diagnostic performance and total radiation dose of hybrid MPI for detection of significant CAD compared with sequential assessment using nuclear MPI after coronary CT.Methods and Results:The results for 101 patients who underwent coronary CT, nuclear MPI and invasive coronary angiography within 3 months of all imaging were analyzed. We calculated the summed difference score (SDS) from standard nuclear MPI and hybrid SDS from hybrid MPI, which revealed myocardial ischemia. The diagnostic performance of SDS and hybrid SDS for detecting significant CAD was analyzed using receiver-operating characteristic (ROC) curve analysis. We also compared the total radiation dose of both methods. The area under the ROC curve was not different between SDS and hybrid SDS (0.901 and 0.815, P=0.079). Total radiation dose of hybrid MPI was significantly lower than standard nuclear MPI with CT angiography (4.62 mSv vs. 9.72 mSv, P<0.0001). CONCLUSIONS: Hybrid MPI showed a precise diagnostic accuracy for significant CAD detection.


Subject(s)
Computed Tomography Angiography/methods , Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Coronary Stenosis/diagnostic imaging , Exercise Test , Myocardial Perfusion Imaging/methods , Rest , Adenosine/administration & dosage , Aged , Cardiotonic Agents/administration & dosage , Data Accuracy , Dobutamine/administration & dosage , Female , Humans , Male , Middle Aged , Radiation Dosage , Retrospective Studies , Vasodilator Agents/administration & dosage
15.
BMC Cardiovasc Disord ; 20(1): 416, 2020 09 14.
Article in English | MEDLINE | ID: mdl-32928125

ABSTRACT

BACKGROUND: Low-dose dobutamine stress echocardiography (DSE) is indicated in patients with low flow (stroke volume index [SVi] < 35 ml/m2) low gradient (mean pressure gradient < 40 mmHg) and left ventricular ejection fraction (LVEF) < 50% aortic stenosis (AS) to assess LV contractile reserve (> 20% increase in SVi) and severity grade of AS. Severe AS is defined by a mean pressure gradient of 40 mmHg occurring at any time during the test when aortic valve area remains < 1.0 cm2. CASE PRESENTATION: This case report highlights the utility of mitral annular systolic velocity (S') by tissue Doppler imaging and peak LV outflow tract (LVOT) velocity as markers of LV intrinsic contractile function during DSE in a patient with low flow low gradient AS and reduced EF prior to transcatheter aortic valve implantation (TAVI). CONCLUSIONS: Mitral annular S' and peak LVOT velocities are reliable markers of LV intrinsic contractile function and should be incorporated into routine low-dose DSE.


Subject(s)
Adrenergic beta-1 Receptor Agonists/administration & dosage , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve/diagnostic imaging , Dobutamine/administration & dosage , Echocardiography, Doppler , Echocardiography, Stress , Aged, 80 and over , Aortic Valve/physiopathology , Aortic Valve/surgery , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/surgery , Hemodynamics , Humans , Male , Predictive Value of Tests , Recovery of Function , Severity of Illness Index , Transcatheter Aortic Valve Replacement , Treatment Outcome , Ventricular Function, Left
16.
Int J Cardiovasc Imaging ; 36(10): 1953-1962, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32757119

ABSTRACT

Negative stress echocardiography (NSE) is associated with low cardiovascular morbidity and overall mortality. We aimed to determine the clinical and echocardiographic predictors of overall and cardiovascular outcomes following NSE. Patients who underwent SE between 2013 and 2017 were reviewed. Patients with a history of solid organ transplant or being evaluated for transplant, history of end-stage renal or liver disease, and positive SE were excluded. NSE results were divided into negative diagnostic if patient reached target heart rate (THR) and had no wall motion abnormality (WMA) at rest or stress; negative non-diagnostic if patient had no WMA but did not reach THR or if image quality was non-diagnostic; and abnormal non-ischemic if patient had a resting WMA not worsened at stress along with a personal history of coronary artery disease (CAD). New CAD lesion at 1 year was defined as ≥ 50% stenosis on cardiac catheterization. Of 4119 patients with SE, 2575 were included. All-cause mortality rate was 1.1%/year and CAD rate was 3.1%/year. Predictors of all-cause mortality were age, male gender, history of smoking and being selected for dobutamine SE. Predictors of a new CAD lesion at 1 year were male gender, diabetes, personal history of CAD and abnormal non-ischemic SE. We identified clinical and echocardiographic characteristics in a subset of NSE patients who are at higher risk for subsequent adverse events. These characteristics should be accounted for during the clinical interpretation of SE, and patients found at increased risk for morbidity and mortality warrant continued follow-up.


Subject(s)
Coronary Artery Disease/diagnostic imaging , Echocardiography, Stress , Exercise Test , Adrenergic beta-1 Receptor Agonists/administration & dosage , Aged , Coronary Artery Disease/mortality , Coronary Artery Disease/physiopathology , Dobutamine/administration & dosage , Female , Heart Rate , Humans , Male , Middle Aged , Predictive Value of Tests , Prognosis , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors
17.
Anatol J Cardiol ; 24(2): 83-91, 2020 08.
Article in English | MEDLINE | ID: mdl-32749255

ABSTRACT

OBJECTIVE: Early identification of viable myocardium in ischemic cardiomyopathy (ICM) patients is essential for early intervention and better clinical outcome. 99mTechnetium (99mTc) sestamibi gated myocardial perfusion imaging (gMPI) is a well-established technique for myocardial viability evaluation. Detection of potentially viable segments is a predictor of hibernating myocardium. ICM patients with hibernation have a better prognosis after revascularization. We used a novel infusion technique to determine better viability detection preoperatively in challenging situations. Like thallium, does prolonged availability of sestamibi in circulation with additional low dose dobutamine steady infusion (DS Inf) facilitate improved myocardial viability? METHODS: A total of 58 ICM patients with infarct and left ventricular ejection fraction (LVEF) <45% underwent 99mTc sestamibi bolus injection followed by slow intravenous infusion single-photon emission computed tomography (SPECT) using a 2 day protocol. After acquiring the second set of 99mTc sestamibi infusion images, a third SPECT gMPI was performed during DS Inf. RESULTS: A 17-segment myocardial model was used; 52 of 58 patients (548/986 segments) demonstrated perfusion defects (nonviable myocardium) on bolus study. Only 24 patients demonstrated viable segments by standard bolus imaging protocol. The slow MIBI infusion study demonstrated 158 viable segments (12 ICM patients), while combined infusion (99mTc sestamibi+DS Inf) exhibited an additional 6 patients with improved myocardial viability. Thus, 18 high risk patients benefited by this novel infusion technique to demonstrate viable myocardium on SPECT. There was a significantly higher sensitivity (p=0.05) and positive predictive value (p=0.01) in viability identification with the combined DS Inf technique. In dysfunctional segments, the rate of concordance for detecting viability between infusion and bolus techniques was 65%. Paired t test showed statistically significant improvement in viability detection with combined infusion compared to the bolus study (p=0.001). CONCLUSION: This novel infusion technique was shown to be feasible and incremental in viability detection in ICM patients with severe left ventricular dysfunction. It is a robust tool to guide revascularization, in high risk ICM patients. This study also showed that patients with large transmural MI demonstrated no significant improvement in myocardial perfusion status using either protocol.


Subject(s)
Cardiotonic Agents/administration & dosage , Dobutamine/administration & dosage , Myocardial Ischemia/diagnostic imaging , Radiopharmaceuticals/administration & dosage , Technetium Tc 99m Sestamibi/administration & dosage , Adult , Aged , Drug Administration Schedule , Echocardiography , Female , Humans , Infusions, Intravenous , Male , Middle Aged , Predictive Value of Tests , Tomography, Emission-Computed, Single-Photon
18.
Yakugaku Zasshi ; 140(7): 869-875, 2020.
Article in Japanese | MEDLINE | ID: mdl-32612048

ABSTRACT

In recent years, home medical care has been strongly promoted. As a consequence, the conditions managed in home medical care have become increasingly diverse. Heart failure is one of the most common disorders after malignant diseases. Patients with chronic heart failure (CHF) are often forced into hospitalization because of the inability to control symptoms with oral medications, even though they hope to stay at home. Recently, we have experienced a case where the patient required continuous administration of dobutamine at home. In order to carry out CHF care at home successfully, it is necessary to adjust the doses of catecholamine and furosemide swiftly in response to changes in patients' conditions. In this case, the patient was able to spend four months at home thanks to the cooperation of a team of a physician, nurses, and pharmacists. Catecholamine-dependent patients with terminal CHF require expensive medical infusion pumps for precise administration. However, the economic assistance to such patients remains insufficient. Furthermore, dobutamine and furosemide injections are not dispensed extramurally, and therefore might become an impediment to the cooperation of the team. In this symposium, I consider and discuss the role of pharmacists in a home medical care team for patients with terminal CHF.


Subject(s)
Heart Failure/drug therapy , Home Care Services , Patient Care Team , Pharmacists , Professional Role , Catecholamines/administration & dosage , Chronic Disease , Dobutamine/administration & dosage , Furosemide/administration & dosage , Humans , Injections
20.
Open Heart ; 7(1)2020 06.
Article in English | MEDLINE | ID: mdl-32587105

ABSTRACT

OBJECTIVE: Due to the low prevalence of obstructive coronary artery disease (CAD) in women, stress testing has a relatively low predictive value for this. Additionally, conventional cardiovascular risk scores underestimate risk in women. This study sought to evaluate the role of atherosclerosis assessment using carotid ultrasound (CU) in women attending for stress echocardiography (SE). METHODS: This was a prospective study in which consecutive women with recent-onset suspected angina, who were referred for clinically indicated SE, underwent CU. RESULTS: 415 women (mean age 61±10 years, 29% diabetes mellitus, mean body mass index 28) attending for SE underwent CU. 47 women (11%) had inducible wall motion abnormalities, and carotid disease (CD) was present in 46% (carotid plaque in 41%, carotid intima-media thickness >75th percentile in 15%). Women with CD were older (65 vs 58 years, p<0.001), and more likely to have diabetes (41% vs 21%, p=0.001), hypertension (67% vs 36%, p<0.01) and a higher pretest probability of CAD (59% vs 41%, p<0.001). 40% of women classified as low Framingham risk were found to have evidence of CD.The positive predictive value of SE for flow-limiting CAD was 51%, but with the presence of carotid plaque, this was 71% (p<0.01). Carotid plaque (p=0.004) and ischaemia (p=0.01) were the only independent predictors of >70% angiographic stenosis. In women with ischaemia on SE and no carotid plaque, the negative predictive value for flow-limiting disease was 88%.During a follow-up of 1058±234 days, there were 15 events (defined as all-cause mortality, non-fatal myocardial infarction, heart failure admissions and late coronary revascularisation). Age (HR 1.07 (1.00-1.15), p=0.04), carotid plaque burden (HR 1.65 (1.36-2.00), p<0.001) and ischaemic burden (HR 1.41 (1.18-1.68), p<0.001) were associated with outcome. There was a stepwise increase in events/year from 0.3% when there were no ischaemia and atherosclerosis, 1.1% when there was atherosclerosis and no ischaemia, 2.2% when there was ischaemia and no atherosclerosis and 10% when there were both ischaemia and atherosclerosis (p<0.001). CONCLUSION: CU significantly improves the accuracy of SE alone for identifying flow-limiting disease on coronary angiography, and improves risk stratification in women attending for SE, as well identifying a subset of women who may benefit from primary preventative measures.


Subject(s)
Angina Pectoris/diagnostic imaging , Carotid Artery Diseases/diagnostic imaging , Carotid Intima-Media Thickness , Coronary Artery Disease/diagnostic imaging , Echocardiography, Stress , Adrenergic beta-1 Receptor Agonists/administration & dosage , Aged , Angina Pectoris/etiology , Angina Pectoris/mortality , Carotid Artery Diseases/complications , Carotid Artery Diseases/mortality , Coronary Artery Disease/complications , Coronary Artery Disease/mortality , Dobutamine/administration & dosage , Exercise Test , Female , Heart Disease Risk Factors , Humans , Middle Aged , Predictive Value of Tests , Prognosis , Prospective Studies , Reproducibility of Results , Risk Assessment , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...